Expand Bumping this as I just tried this on our Mitsubishi with an 18i-MB and I wasn't successful. When I run the main program, I get an "071 data not found" alarm. Any ideas? For what it's worth, this is also the only fanuc control I've ever touched where I can't start a program and go into edit mode to move wherever I want in the program. I have to use GOTO statements for mid-starting ...
The machine is a Hartford HCMC-2082 with fanuc 32i with the G54.2 rotary table dynamic fixture offset ( rtdfo ) function.
FANUC 31i-B5 5-Axis VMC and FANUC 31i-B 4-Axis HMC are what I'm looking at at the moment. I've got a few FANUC Manuals and none have 5109 listed that I can find. That Parameter Section however relates to Canned Cycles. So unless you're doing some sort of Canned Cycle, that parameter may not be the answer. I'll poke around and see what I can dig up.
FANUC gives builders WIDE latitude in what they can do, and how they can do it. Matsuura, FANUC Robodrill, and others I'm sure use NC Parameters, Keep Relays AND PMC Data bits.
I have read up a little on the "G05.1" command for the older style Fanuc control. The newer 16i was a lot easier to comprehend. I was hoping somebody out there could give me a run down in english (control manual reference). From what I can gather, and correct me if I am wrong, the output shoud be...